KE-ERV-V600 fresh-air purifier

The Tower Series model with twice the airflow, built for classrooms, open-plan offices, villas and cafés. Its six jet outlets spread filtered fresh air across a large area.

600 m³/hfresh-air flow
99%HEPA filtration
82%heat recovery
125 Wat top speed
6 jetsadjustable outlets
100–240 m²recommended area
Applications

600 m³/h for busy spaces

A classroom of 20 pupils, a meeting room of 15 people or a café that fills up at lunchtime produces carbon dioxide and moisture far faster than a small flat. The KE-ERV-V600 is sized for that load: every hour it filters and supplies 600 m³ of outdoor air and sends the same volume of stale air outside. The brochure recommends a floor area of 100–240 m².

Its main applications are schools and public buildings, open-plan offices, the ground floors of villas, clinic waiting areas, gyms and Pilates studios, and cafés and restaurants. Because it needs no ductwork, it can be installed classroom by classroom or office by office in a building that is in use, without one unit affecting another.

Dimensions and placement

The cabinet measures 560 × 460 × 1,700 mm and weighs 65 kg. An external wall facing the centre of the space gives the best distribution. In rooms with high ceilings, angling the outlets slightly upwards helps fresh air rise to the ceiling and spread across the room.

KE-ERV-V600 with six jet outlets in an open-plan office
Distribution

Six outlets for wide-area coverage

The top of the V600 has six supply outlets arranged in two rows, one above the other. Each outlet can be turned individually, so part of the airflow can be directed towards desks and part towards the ceiling. Because the number of outlets doubles along with the airflow, there is no strong draught from a single point.

Room air is drawn in through the side grille. The unit keeps the space under slight positive pressure, reducing the amount of unfiltered air that gets in when doors open and close or through gaps around window frames.

Energy

3.6 kW of heat recovered

The higher the airflow, the more energy is saved. In winter, supplying 600 m³ of outdoor air at 0 degrees to a classroom at 22 degrees every hour would take about 4.4 kW of heating without heat recovery. The exchanger's 82% efficiency brings that load down to about 0.8 kW, with the remaining 3.6 kW or so recovered from the exhaust air.

At this airflow, the fans have a total power input of 125 W. The motors are brushless DC with eight speed settings; in automatic mode, the speed is chosen by the PM2.5 reading.

Fresh-air and exhaust airstreams passing through the cross-flow exchanger without mixing
Technical specifications

Dimensions, power and performance data

The KE-ERV-V600 shown side by side with the smaller KE-ERV-V300.

SpecificationKE-ERV-V600KE-ERV-V300
Fresh-air flow rate600 m³/h300 m³/h
Recommended floor area100–240 m²50–120 m²
Heat recovery (temperature efficiency)82%
Exchanger typeCross-flow total heat (enthalpy) exchanger
Filter stagesPre-filter, PM2.5 filter, HEPA composite
HEPA filtration efficiency99%
Purification modesPM2.5 · Deep · Ultra (30 min)
Power input125 W70 W
Mains supply220 V~ / 50 Hz
FanBrushless DC, 8 speeds
Sound pressure25–36 dB(A) · sleep mode 23 dB(A)
ControlsTouch panel, wireless remote
Measured valuesPM2.5, temperature, relative humidity
OperationManual, automatic, timer
Supply outlets6 jets (3 + 3)3 jets (single row)
Dimensions (W × D × H)560 × 460 × 1,700 mm560 × 410 × 1,580 mm
Weight65 kg55 kg
InstallationFloor-standing, ductless
CertificationCE

Values are nominal figures measured under the manufacturer's test conditions. Source: K Enerji Tower Series Product Brochure (2026).

Inside the Tower Series: supply and exhaust fans, exchanger, HEPA, PM2.5 and pre-filters
Maintenance

Filter replacement schedule

The cover opens with a key and the filters slide out from the front along their rails; the unit is powered off while the cover is open. Recommended intervals for typical urban conditions:

ComponentInterval
Fresh-air pre-filterWash every 1–2 months, replace every 3 months
Return-air pre-filterWash every 1–2 months, replace every 6 months
PM2.5 filter6 months
HEPA composite filter12 months
Heat exchangerClean or replace every 3 years

In areas with heavy traffic, construction sites or industry, check the filters more often.

Images

The KE-ERV-V600 in use

KE-ERV-V600 front view with six jet outlets
KE-ERV-V600 front view with six jet outlets
KE-ERV-V600 internal layout with the cover open
KE-ERV-V600 internal layout with the cover open
KE-ERV-V600 in a clinic waiting area
KE-ERV-V600 in a clinic waiting area
PDFProduct brochure (PDF, Turkish)KE-ERV-V300 · KE-ERV-V600 · 16 pages · Turkish · 5.7 MBDownload
Questions

Questions about the KE-ERV-V600

Is the KE-ERV-V600 enough for a classroom?

At 30 m³/h per person, an airflow of 600 m³/h covers about 20 people. It suits a classroom of up to 20 pupils; for larger classes we size the system together with the room volume.

Is the larger model noisier?

No. The brochure gives the same sound levels for both models: 25 to 36 dB(A) depending on speed, and 23 dB(A) in sleep mode at night.

How much heat is recovered at 600 m³/h?

With outdoor air at 0 °C and indoor air at 22 °C, about 3.6 kW. Most of the roughly 4.4 kW needed to heat the fresh air is covered by the exchanger.

Who changes the filters?

The filters slide out from the front without tools, so users can change them themselves. If you prefer, K Enerji can take care of periodic maintenance and filter supply.

Can it replace a kitchen hood in a café or restaurant?

No. The unit meets the general fresh-air needs of the space and dilutes odours and moisture. Cooking areas still need their own hood and extract system.

Planning a school, office or villa project?

Send us a list of rooms and occupancy figures; together we will work out how many units you need and plan the installation.